Product Name | Key features and specifications | Benefits | Applications |
---|---|---|---|
Fibre Concrete |
Polypropylene
microfibres
All grades
Slump -
100mm +/-25 Steel Fibres: All grades - 20 kg min, Slump - 75 +/-25 (Dosage will depend on specifications) |
Reduces plastic shrinkage cracking Replaces the secondary steel (mesh) reinforcement in floors |
For non-structural slabs on the ground, such as driveways Structural slabs on ground |
Early Strength Concrete | All grades, Slump - 75mm to 90mm +/-25, Strength - 18MPa a t 72 hours from last concrete delivered Strength - more than 10MPa at 24 hours or more than 20MPa at 72 Hours Rapid strength development using calcium aluminate binder, Min. 400kg/m3 cement and w/c below 0.4 |
Achieves 18MPa at 72 hours, for post tensioning Gain time on job site Can achieve minimum 30MPa at 8 hours |
Precast, building construction using formwork involving post tensioning Horizontal and vertical applications Airport runways / Road repairs / Emergency repairs to any concrete structure |
Flowable Concrete | All grades, Sump - 160m to 200mm, special admixture ensures slump retention for 90min, Reduced shrinkage, aggregates 26mm or less Flow over 640mm with 2 hours slump retention, viscosity 6 to 8 seconds with 0 funnel, Aggregates: 13mm or less Mix formulated for horizontal applications Flow over 640mm with 2 hours slump retention, viscosity 6 to 8 seconds wiht 0 funnel, Aggregates: 13mm or less, Mix formulated for vertical applications |
Flowable concrete from the plant to
the job site, addition of extra water
must be prevented, better finishing
(less bleeding, less cracks), better workability and easier to cast Easy to place and finish (will require technical assistance) Easy to place and finish (will require technical assistance) |
Pumping in horizontal applications, such as slabs or driveways, vertical formwork applications Used for floor slabs and toppings, can be pigmented, necessity of curing with a Lafarge curing compound Difficult access areas, congested reinforcing, specialised repairs, architectural finishes, necessity of curing with a Lafarge curing compound |
Waterproof Concrete | Spec to suit requirement, using Xypex admixture, Min. c/w=1.9 Min. cementitious 300kg/m3, Site control very important, All contracts to be discussed with Xypex | For high spec waterproof requirements, warranty provided if Xypex site service is used | Water tanks, basements, floor slabs, decks |
Pool Concrete | Semi-dry concrete specially designed for handpack operation (slump below 75mm), can add polypropylene fibres | Quality and consistency of the concrete | Lining swimming pools and ponds |
Foam Concrete | Low density 1200-1500kg/m3 or 1600-1800kg.m3 concrete with a compressive strength of 3 to 5MPa | Low density concrete allowing easy removal if necessary | Trench, tank reinstatements, non structural insulations |
Light Concrete | Light weight 25MPa concrete, perlite or polystyrene beads used to achieve a density below 1100kg/m3 | Light weight concrete | Lightweight work |
Industrial Floor Concrete | High strength, low shrinkage concrete freatures reduced curling, with of without fibres, Min. strength 30MPa, achieves flatness less than .045 micron/Lm, slump 75mm, Cement min. 310kg/m3, Max. 20% extender, W/C max 0.53 | High performance concrete | Industrial floors |
Aqua Concrete | Underwater concrete mixed to suit job specification, Min. 30MPa | Under water application | Under water construction |
Piling Concrete | Dry or semi dry piling mix, 30MPa 30Mpa Tremmie mix for piling applications, slump - 180mm to 220mm 30MPa Grout mix, 20 sec flow through a Marsch Cone |
Specialised piling mix for dry applications Ease of placement with Tremmie pipes Used where pumping grouts is an advantage |
Piling Piling Piling |